Get a Quote Miachina
Products AHE Series AHE Industrial Unit MIA-AHE1500GL
MIA-AHE1500GL Industrial ERV 15000 m³/h
AHE Series · Industrial · 15000 m³/h

MIA-AHE1500GL Industrial Energy Recovery Ventilator

米亚超大型工业热回收新风机组 — Very large industrial energy recovery ventilator for major commercial buildings, large industrial plants, and campus-scale facilities. 15000 m³/h rated airflow delivered by a triple industrial centrifugal fan assembly on a 380V 3-phase 5500W drive. Walk-in service access panels, modular filter sections, and full BMS/DDC integration via Modbus and BACnet. Designed for the scale of large commercial buildings, hospitals, and industrial complexes where a single high-efficiency AHU serves multiple ventilation zones.

15000 m³/h
Rated Airflow
85%
HR Efficiency
Multi-Stage
Filtration
Ø800 mm
Duct Connection

Technical Highlights

The AHE1500GL introduces the triple fan configuration, walk-in service access panels, and a full BMS/DDC integration suite — built for large commercial and industrial facilities where ventilation continuity, service access, and intelligent control are critical requirements.

Triple Fan Assembly
Triple Industrial Centrifugal Fan Assembly
Three independently driven 380V 3-phase industrial centrifugal fans provide 15000 m³/h total airflow with N+1 redundancy — the unit continues to operate at 67% capacity if one fan requires service or fails. Each fan is fitted with a VFD (variable frequency drive) for proportional speed control. The triple arrangement allows staged start-up to limit inrush current in electrically sensitive environments. Fan bearings are designed for 100,000+ hours continuous industrial duty at rated speed.
Walk-In Service Access
Walk-In Service Access Panels
At this scale, the AHE1500GL features full-height hinged service doors on both supply and return sections — providing walk-in access to all internal components. Facility engineers can physically enter the unit to inspect, clean, and replace exchanger cores, filter banks, fans, and instrumentation without partial disassembly. Modular filter sections slide out independently for replacement during scheduled maintenance windows. Designed to meet commercial and industrial facility management standards for service accessibility.
BMS/DDC Integration
BMS / DDC Integration with Modular Filter Sections
Native BMS/DDC integration supports Modbus RTU, Modbus TCP, BACnet IP, and BACnet MSTP protocols — providing full AHU control from the building management system. Monitored parameters include supply and exhaust airflow, fan speed per motor, filter differential pressure across each stage, supply air temperature and humidity, heat recovery efficiency, and fault codes. Modular filter section design allows G4, F7, ESP, and optional H13 HEPA stages to be installed or removed as project requirements change over the building life.

Applications

The AHE1500GL serves as the primary AHU for large-scale facilities where a single energy recovery unit services multiple ventilation zones, floors, or process areas simultaneously.

Large Commercial Buildings
Multi-storey office towers, large hotel complexes, shopping centres, and convention facilities use the AHE1500GL as the central fresh air AHU servicing a floor or entire building. The 15000 m³/h capacity covers a 3000–6000 m² floor plate at standard commercial ventilation rates, with BMS integration enabling zone-by-zone airflow modulation matched to occupancy sensors and CO₂ levels.
Industrial Manufacturing Plants
Process industries — automotive, electronics, food processing, pharmaceutical — require high air change rates with precise temperature and humidity control. The AHE1500GL's 15000 m³/h capacity, combined with multi-stage filtration and VFD fan control, provides the airflow volume and controllability required for demanding process environments. Energy recovery at 85% efficiency delivers measurable operating cost reduction against simple exhaust and makeup-air systems.
Hospital Campuses & Research Facilities
Large hospital campuses with multiple clinical wings, research laboratories, and support facilities use the AHE1500GL with zone isolation dampers and pressure-tracking control to maintain required pressure differentials between clinical areas. DDC integration provides the granular zone-level control required by infection control engineers, while energy recovery reduces the heating and cooling load of the mandatory 100% outdoor air systems used in healthcare.

Product Showcase

Technical Parameters

380V 3-phase · Triple fan assembly · VFD per motor · BMS/DDC Modbus/BACnet · Walk-in service access · Modular filter sections

Model Flow Rate Power Efficiency Noise Duct Ø Dimensions (mm) Weight Voltage
MIA-AHE1500GL15000 m³/h5500W80–85%65–78 dB(A)Ø800 mm6200×2400×25001400 kg380V 3-phase

* VFD standard on each fan motor (3× independent drives). BMS/DDC integration: Modbus RTU, Modbus TCP, BACnet IP, BACnet MSTP standard. Walk-in service access both supply and exhaust sections. Modular filter stages: G4, F7, ESP standard; H13/H14 HEPA optional. Custom duct arrangements and seismic isolation mounts available. Contact our industrial engineering team for project-specific specification.

Related Models

Interested in this model?

Our engineers will help you verify requirements and select the right configuration for your project.

Get a Personal Offer

Make Your Home More Comfortable

Fill out the form to get a personalized MIA equipment offer

✓ Request sent! Our manager will contact you within 1 business day.